Contact

Request a site study

Tell us about your facility. We reply within one working day, usually with a short call and a request for floor plans. The study is free and without obligation.

Send your request

We reply within one working day. Floor plans and room details can follow by email once we have spoken.

Prefer to talk?

Cyprus
Phone
+357 99 643209
Email
icarus222cy@gmail.com
Office
56 Vasileos Pavlou
Agios Dometios, 2363 Nicosia
Greece
Where we work
Cyprus and Greece: site visits, installation and commissioning.
United Kingdom: film and television production.
How it works

From floor plan to installed system

STEP 1
You send the basics
Building type, rooms and ceiling heights, hours of occupancy; for cleanrooms, the grade and the gowning route.
STEP 2
We model the installation
Lamp positions and fluence rate modelled in Illuminate, then checked against the EU exposure limit for 222 nm under Directive 2006/25/EC — and verified on site with point measurements.
STEP 3
You receive a proposal
Devices, positions, expected coverage, price and installation plan. Installation is supervised by Icarus 222; UV222® devices carry a two-year warranty.

What to have ready

Floor plans with ceiling heights (PDF or DWG)
Room use and hours of occupancy
For cleanrooms: grade (A/B, C, D or CNC), gowning route, HVAC air-change rate
Photos of the ceilings and any obstacles — ducts, luminaires, cranes
Your current disinfection protocol, if there is one
CE
UV222® is manufactured by UV Medico A/S, Denmark, around the Ushio Care222® lamp and is CE-marked. Compliance documents are available on request.